Home | Industries | Pharmaceutical| TefloGas Filter Cartridges

TefloGas Filter Cartridges

Hydrophobic PTFE Membrane · Sterilizing Grade

TefloGas Filter Cartridges are composed of a hydrophobic PTFE membrane and a thick thermal-resistance polypropylene core. They are characterized by a high filtration area and non-metallic ion release and are easy to clean when compared to filters with a stainless steel core. As a result, they are highly recommended for air and gas sterile filtration of biological liquids and fermentation and pharmaceutical industries.



Features and Benefits



Quality Standards:



Typical Applications


Materials of Construction


Filter Media

Hydrophobic PTFE Membrane

Support

Polypropylene

Core/Cage/End Caps

Polypropylene




Operating Conditions


Max. Operating Pressure

6.9 bar (100 psi) at 25 °C

4.0 bar (58 psi) at 60 °C

2.4 bar (35 psi) at 80 °C

Max. Differential Pressure

Forward

6.9 bar (100 psi) at 25 °C

4.0 bar (58 psi) at 60 °C

2.4 bar (35 psi) at 80 °C

Reverse

3.0 bar (44 psi) at 25 °C

1.0 bar (15 psi) at 80 °C

Effective Filtration Area0.68m² / Φ 68-10 inch




Sterilization


Inline Steam Sterilization

Up to 100 forward cycles and 50 reverse cycles 

(145℃ for 30min <0.3bar per cycle)

Autoclaveup to 400 cycles (130°C for 30min for every cycle)

 


Integrity Test Data


GPFMP

Bubble Point

BP: ≥ 0.1 MPa (60%/40%IPA/Water)

Diffusion FlowDF: ≤ 24ml/min/10''cartridge @ 80KPa (60%/40%IPA/Water)

Water Intrusion Test

WFT : ≤0.75ml/min/10''cartridge @ 0.25MPa

 

GPFP

Bubble Point

BP: ≥ 0.11 MPa (60%/40%IPA/Water)

Diffusion FlowDF: ≤ 16ml/min/10''cartridge @ 80KPa (60%/40%IPA/Water)

Water Intrusion Test

WFT : ≤0.38ml/min/10''cartridge @ 0.25MPa

 





 



Flow Rate Characteristics



Quality and Biological Safety

  • Integrity Testing
  • All cartridges are integrity tested by the aerosol challenge test methods with VALAIR DATA II. Diffusional Flow<16 ml/min at 0.8bar(11.6psi). Water intrusion<1.35ml/min. Values are for cartridges wetted with 60/40 IPA/Water.
  • Steam Sterilization
  • 71-GPF cartridges can be repeatedly in situ steam sterilizal for up to 150 cycles at 121°C,30min at a maximum differential pressure of 0.5 bar
  • Validation
  • 71-GPF cartridges have been fully validated as sterilizing grade
    filter cartridges, for compressed air and gas applications. It passed the DOP test with DH VALAIR DATA II.



  • Food and Biological Safety

  • Extractables< 30mg per 10 inch
    Endotoxins< 0.25EU/mL
  • Meets the requirements for food contact:  European Regulation (EC) Number 1935/2004


Ordering Infomation


TypeRemoval RatingsEnd CapNominal LengthSeal MaterialIndustry

GPFMP

GPFP






0001=0.01μm

0022=0.22μm







HSF=226 /Fin (PBT Insert)

HSC=226 /Flat (PBT Insert)

HTF=222 /Fin (PBT Insert)

HTC=222 /Flat (PBT Insert)

DOE=Double Open End


05= 5"

10=10"

20=20"

30=30"

40=40"


S=Silicone

E=EPDM

V=Viton

P=PFA/Viton


P=Pharmaceutical






DOWNLOAD