Preparations
Single Use
Utility System
Sterile APIs
Lab/Microbial Limit Tests
Cobetter Instruments
OEM Membranes and Devices
Sintered Porous PTFE
Oxygenation
Air and Vent Filtration
Infusion Therapy
Medical Water Filtration
Surgical Smoke ULPA Filter
Semiconductors
Flat Panel Display
Electronic Chemicals
Data Storage
High Brightness Light Emitting Diode
Brewing
Bottled Water
Wine
Soft Drinks
Dairy
Distilled Spirits
Food and Ingredients
Energy and Chemical Industry
Fine Chemical Industry
Hydraulic & Lubricating System
Machinery & Equipment
Transfer Membrane
Sterility Testing
Groundwater Sampling Filter
Automobile Exhaust Detection Membrane
Car Cleanness Filter Detection Membrane
Atmosphere /Flue Gas Monitoring Membrane
Ultrafiltration Centrifugal Tube
IV Filter
Cobetter IV filters ensure patients safety during intravenous therapies. The filters eliminate inadvertent particulate debris, such as plastic or glass fragments, reducing adverse reactions and immune responses. They also remove gas bubbles from IV lines, significantly minimizing the risk of air embolisms. Cobetter IV filters are equipped with high quality PES membrane and PTFE membrane.
The Main Function of Infusion Therapy Filters
· Air elimination. Cobetter hydrophobic membrane which enables them to remove gas bubbles from infusion solutions, significantly minimizing the risk of gas emboli.
· Particle removing. The specif filter 0.2μm membrane reliably and safely protects against particles (like rubber abrasion, glass splinters) through skin or air contact.
· Low protein binding.Maximizes delivery of drugs with double side low protein binding PES membrane.
· Retention of Bacteria and Bacterial Endotoxins. The endotoxin retention is achieved by the positive charging of the filter membrane of 0.2μm of 96 h.
· Small, compact design makes it ideal for alternate site and ambulatory care applications.
· Easy assembly. Small, compact design makes it ideal for alternate site and ambulatory care applications.
To know more about the 0.2μm and 1.2μm IV filte
Introductions of 0.2μm and 1.2μm IV filter.
· 0.2μm IV infusion filter:The membrane passed the B. diminuta Filtration Efficiency Test, and the challenge level reaches that LRV≥107CFU/cm2 per ASTM F838 test methods.
· 1.2μm IV infusion filter:The membrane passed the Candida Albicans Filtration Efficiency Test,and the challenge level reaches that LRV ≥ 107CFU/cm2.
Structures & Advantages
Cobetter IV filters are equipped with high quality PES membrane and PTFE membrane.
Double-layer PES membranes, expand the effective filtration area, realize a stronger dirt holding capacity, and faster liquid flow rate.
Cobetter PES membrane has regular and uniform filter pores, high filtration accuracy, no foreign matter shedding, less drug adsorption, and a longer service life. Strictly grading the pore size, you can choose the appropriate pore size according to clinical needs.
to know more about Cobetter PES membrane
Eight venting holes with Oleophobic PTFE membrane, located close to the upstream and downstream positions, can better exhaust, avoid gas bubbles entering into human body, ensure long-term hydrophobic performance without leakage, at the same time reduce the operational restrictions in clinical applications.
to know more about Cobetter Oleophobic PTFE membrane
Specifications
Housing |
|
|
|
|
|
|
|
|
|
0.2 μm | Standard Connectors: Outer Diameter : Φ 3.6 mm Length: | Filter Media: Vent: | 3.2 bar | 3.2 bar | 25 mL/min | <2.5 mL | < 0.25 EU/mL | 9 g | Eto |
1.2 μm | 3.2 bar (46 psi) | 1.2 bar | 60 mL/min at 100 cm head pressure | <2.5 mL | < 0.25 EU/mL using the LAL test method | 9 g | Eto | ||
3.0 μm | 3.2 bar (46 psi) | 0.45 bar | 120 mL/min at 100 cm (39 in.) head pressure | <2.5 mL | < 0.25 EU/mL using the LAL test method | 9 g | Eto | ||
5.0 μm | 3.2 bar (46 psi) | 0.27 bar | 150 mL/min at 100 cm (39 in.) head pressure | <2.5 mL | < 0.25 EU/mL using the LAL test method | 9 g | Eto |
Applications
· Aqueous IV Solutions · IV Fluid Delivery Filtration · Endotoxin Retentive Filter Application · Chemotherapy · Antibiotic Therapy · Nutrient Admixture Filter Application | · TPN and Lipid Containing Solutions · Drug Therapy · Infusion Therapy · Saline Filtration · Any process requiring the removal of entrapped air from liquid solutions |
Ordering Information
Type No | Pore Size | Description |
CBT IV 00220001DTE | 0.2 μm | PES membrane, clear housing, SIV connectors |
CBT PC 00220001DTE | 0.2 μm | Positively charged PES membrane, clear housing, SIV connectors |
CBT IV 01200001DTE | 1.2 μm | PES membrane, clear housing, SIV connectors |
CBT IV 03000001DTE | 3.0 μm | PES membrane, clear housing, SIV connectors |
CBT IV 05000001DTE | 5.0 μm | PES membrane, clear housing, SIV connectors |
Production Workshop
For technical data sheet or application inquiry, you are more than welcome to contact our sales representative by sales@cobetterfilter.com or leave a message
Hangzhou Cobetter Filtration Equipment Co.,Ltd
Tel
86-571-87704359(English)
86-571-87704270(Japanese)
sale@cobetterfilter.com
Sales
19/F, Building B, Huanyu Business Center, No.626 Kejiguan Road Binjiang District, Hangzhou 310052, China
Factory
Heshang Industry Section,Xiaoshan,Hangzhou 310053,China
COPYRIGHT 2019 Cobetter Filtration Equipment Co.,Ltd ALL RIGHTS RESERVED.
Web design:Hangzhou dingyi information technology co.,Ltd