Preparations
Single Use
Utility System
Sterile APIs
Lab/Microbial Limit Tests
Cobetter Instruments
OEM Membranes and Devices
Sintered Porous PTFE
Oxygenation
Air and Vent Filtration
Infusion Therapy
Medical Water Filtration
Surgical Smoke ULPA Filter
Semiconductors
Flat Panel Display
Electronic Chemicals
Data Storage
High Brightness Light Emitting Diode
Brewing
Bottled Water
Wine
Soft Drinks
Dairy
Distilled Spirits
Food and Ingredients
Energy and Chemical Industry
Fine Chemical Industry
Hydraulic & Lubricating System
Machinery & Equipment
Transfer Membrane
Sterility Testing
Groundwater Sampling Filter
Automobile Exhaust Detection Membrane
Car Cleanness Filter Detection Membrane
Atmosphere /Flue Gas Monitoring Membrane
Ultrafiltration Centrifugal Tube
BriScale™ VF disposable vacuum filter / storage systems, provides a complete solution for your filtering needs. The vacuum filtration system consists of a polystyrene filter funnel joined by an adapter to a removable receiver / storage bottle, which can be easily unscrewed from unit and can be sealed with a plug cap for filtrate storage.
BriScale™ VF for Filtration of High Viscosity Fluids Media
In R&D process of biological laboratories, many samples are filtered, separated and purified everyday. The chemical properties, particle size, water solubility, viscosity, and protein characteristics of the filter medium will affect the difficulty of separation and purification. Vacuum Filter Unit, a frequently used lab filtration device, can provide the best filtering solution accordingly.
BriScale™ VF Bottle Tops and Filter Units uses vacuum filtration to provide power, which can not only increase the flow rate and flux, but also reduces the retention volume of the medium to be filtered. It can be used for filtration of high viscosity fluids media.
In terms of sterilization and filtration of cell culture media, buffers, etc., BriScale™ VF can be equipped with different material membranes such as PES, PVDF, PTFE, etc.
In addition, BriScale™ VF can use a special test kit to achieve integrity testing. The vacuum filtration product in China that supports integrity testing, which effectively guarantees the sterility of filtered samples.
Structure Diagram
Application Cases
Membrane Material | Filtration Area | Retention Volume | Vacuum Degree | Test Solution | Filtration Volume |
Purcise SLE 0.22μm ① | 19.6 cm² | 1.43 mL | -0.4 bar | DMEM (Serum Free) | 150 mL |
①:According to ASTM F838 method,it can pass the interception test of 107 cfu/cm² Brevundimonas diminuta (ATCC ®19146)
Membrane Sizes
· 150mL funnel contain diameter 50mm membrane filter
· 250mL funnel contains diameter 50mm membrane filter
· 500mL funnel contains diameter 70mm membrane filter
· 1000mL funnel contains diameter 90mm membrane filter
Membrane Types
· Purcise® MLE 0.1μm: Remove Mycoplasma Level PES series
· Purcise® SLE 0.22μm:Remove Bacterial Level PES series
· Purcise® PAF 0.45:Reduce Bacterial Level PES series
· Corevital® SMD 0.22μm:Remove Bacterial Level PVDF series
· SPF 0.22μm:Remove Bacterial Level PTFE series(suitable for filtering high corrosion material),
· Cobetter also can choose to use nylon and other materials to make double layer membrane configuration by referring to materials’ properties.
Features and Advantages
· The scale line is clear and accurate;
· The product is with light body, thick cup wall, low center of gravity, and wide bottleneck, which makes it easier to pour out the samples smoothly;
· The connector is designed with threaded teeth shape to avoid side leakage risk;
· The multi-stage design of the external vacuum interface is suitable for various specifications of hoses;
· BriScale™ VF Single Use Bottle Top Filter and the receiver/storage bottle can be provided separately. · We deal the product with gamma irradiation sterilization, and sterile, dust proof double - layer packaging. So, it can be used directly.
· All membrane types are tissue culture compatible, and heat-sealed to the support grid to maximize flow rate, and reduce foaming and protein denaturization
Application
· Used for the vacuum filtration of buffer, media and components, biological fluids, and other aqueous solutions.
· Used for filtration of tissue culture nutrient solution, biofluid and positioning buffer;
· Used for filtering cell culture medium and other aqueous solution;
· Used for filtering the solution that enable to be sterilized by autoclave.
Ordering Information
Item | Type | Size | Material of membrane | Market |
VF | C = Whole Vacuum Filter Unit B = Receiver Bottle only F = Bottle Top Filter only | 150 = 150mL 250 = 250mL 500 = 500mL 01L = 01L | MLEN = PES 0.1 μm SLEN = PES 0.22 μm PAFS = PES 0.45 μm SPFN = PTFE 0.22 μm SMDN = PVDF 0.22 μm 0000 = only Receiver Bottle SLES = PES 0.45 + 0.22 μm MLEB = PES 0.22 + 0.1 μm SAFS = PES 0.45 + 0.22 μm SMDS = PVDF 0.45 + 0.22 μm | M |
For technical data sheet or application inquiry, you are more than welcome to contact our sales representative by sales@cobetterfilter.com or leave a message
Hangzhou Cobetter Filtration Equipment Co.,Ltd
Tel
86-571-87704359(English)
86-571-87704270(Japanese)
sale@cobetterfilter.com
Sales
19/F, Building B, Huanyu Business Center, No.626 Kejiguan Road Binjiang District, Hangzhou 310052, China
Factory
Heshang Industry Section,Xiaoshan,Hangzhou 310053,China
COPYRIGHT 2019 Cobetter Filtration Equipment Co.,Ltd ALL RIGHTS RESERVED.
Web design:Hangzhou dingyi information technology co.,Ltd