Home | Industries | Pharmaceutical| FluoroPV Filter Cartridges

FluoroPV Filter Cartridges

Hydrophilic PVDF Membrane · Sterilizing Grade

Cobetter FluoroPV Filter Cartridges are made of hydrophilic polyvinylidene fluride (PVDF) membrane characterized by low extractable and protein binding. They are suitable for the sterilized filtration of pharmaceutical liquids such as ophthalmic liquids, biological and other diluted preservative solutions.


Features and Benefits



Quality Standards:

Typical Applications

Materials of Construction


Filter Media

LHPVND Single-Layer Hydrophilic PVDF Membrane

DLHPVNDR Double-Layer Hydrophilic PVDF Membrane

Support

Polypropylene

Core/Cage/End Caps

Polypropylene




Operating Conditions


Max. Operating Pressure

6.9 bar (100 psi) at 25 °C

4.0 bar (58 psi) at 60 °C

2.4 bar (35 psi) at 80 °C

Max. Differential Pressure

Forward

6.9 bar (100 psi) at 25 °C

4.0 bar (58 psi) at 60 °C

2.4 bar (35 psi) at 80 °C

Reverse

3.0 bar (44 psi) at 25 °C

1.0 bar (15 psi) at 80 °C

Effective Filtration Area0.58m² / Φ 69-10 inch




Sterilization


Inline Steam Sterilization

up to 100 forward cycles and 50 reverse cycles

( 135 °C for 30 min < 0.3 bar per cycle )

Autoclaveup to 400 cycles (130°C for 30min per cycle)

 



Integrity Test Data


Bubble Point

BP: ≥ 0.32 MPa(water), LHPVND(0.22 μm)

Diffusion FlowDF: ≤ 20 ml/min/10”@ 0.28 MPa, LHPVND(0.22 μm)

 





 



Flow Rate Characteristics



Biological Safety

Extractable(NVR)<30mg/10" ( Test Procedure:Steaming sterilized for 30min at 121°C, then soaked in the purified water for 24 hours )
OxidabilityMeets FDA for Oxide Test ( Test Procdure: Steaming sterilized for 30min at 121°C, then take the sample after purified water washing )
Endotoxin<0.25Eu/ml , according to LAL Test
Material SafetyMeets USP<88>, for class VI-121°C plastics



Integrity Test Parameters

LHPV0.1μm0.22μm0.45μm
Diffusion Flow(10″Cartridge @20°C)≤30ml/min @3860mbar≤20ml/min @2800mbar/
Bubble Point (in water @20°C)≥4800mbar≥3200mbar≥1200mbar
DLHPV0.1+0.1μm0.22+0.1μm0.22+0.22μm0.45+0.22μm
Diffusion Flow (10″Cartridge @20°C)≤15ml/min @3860mbar≤20ml/min @3860mbar≤18ml/min @2800mbar≤20ml/min @2800mbar
Bubble Point (in water @20°C)≥4800mbar≥4800mbar≥3200mbar≥3200mbar

The Integrity test is a non-destructive test that can be performed by the user to ensure the filter is installed correctly and ready for operation.


Ordering Infomation


TypeRemoval RatingsEnd CapNominal LengthSeal MaterialIndustry

LHPVND 








DLHPVNDR

0010=0.1μm

0022=0.22μm

0045=0.45μm

0065=0.65μm

0100=1.0μm




2222=0.22+0.22μm

2245=0.22+0.45μm

6545=0.64+0.45μm

2210=0.22+0.1μm

4545=0.45+0.45μm

6522=0.65+0.22μm

6510=0.65+0.1μm

4510=0.45+0.1μm


HSF=226 /Fin (PBT Insert)

HSC=226 /Flat (PBT Insert)

HTF=222 /Fin (PBT Insert)

HTC=222 /Flat (PBT Insert)

DOE=Double Open End


05= 5"

10=10"

20=20"

30=30"

40=40"


S=Silicone

E=EPDM

V=Viton

P=PFA/Viton


P=Pharmaceutical






DOWNLOAD

Contact Form