FluoroPV Filter Cartridges
Hydrophilic PVDF Membrane · Sterilizing Grade
Cobetter FluoroPV Filter Cartridges are made of hydrophilic polyvinylidene fluride (PVDF) membrane characterized by low extractable and protein binding. They are suitable for the sterilized filtration of pharmaceutical liquids such as ophthalmic liquids, biological and other diluted preservative solutions.
Low extractable and protein binding
Broad chemical compatibility and temperature resistance
Great durability proven by testing forward/reverse pulse up to 100x
Manufactured in a facility which adheres to ISO 9001: 2015 Practices .
Full Regulatory Compliance with following :
• Bacterial Endotoxin : Aqueous extraction of autocalved filter contains <0.25 EU/ml as determined by Limulus Amebcyte Lysate (LAL),USP<85>.
• Non-fiber Releasing : Component materials meet the criteria for a "Non-fiber-releasing filter" as defined in 21 CFR 210.3(b)(6).
• Component Material Toxicity :Meet the requirement of USP <87> In Vitro Cytotoxicity Test ; Meet the Criteria of USP<88> Biological Reactivity Test for Class VI-121℃ plastics
• TOC/Conductivity at 25 ℃:Autoclaved filter effluent meet the USP<643> for Total Organic Carbon and USP<645> for
• Water Conductivity per WFI requirements after a UPW flush of specified volume .
• Particle Shedding : Autoclaved filter effluent meet the USP<788>for large volume Injections .
• Indirect Food Additive:All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182 , and EU framework regulation [1935/2004/EC].
Antibiotics
Aggressive Solvents
Biologicals Agents
Blood Products
Cold and Hot WFI
Chemicals
Ophthalmic Solutions
Sanitizing Agents
Materials of Construction
Filter Media | LHPVND Single-Layer Hydrophilic PVDF Membrane DLHPVNDR Double-Layer Hydrophilic PVDF Membrane |
Support | Polypropylene |
Core/Cage/End Caps | Polypropylene |
Operating Conditions
Max. Operating Pressure | 6.9 bar (100 psi) at 25 °C 4.0 bar (58 psi) at 60 °C 2.4 bar (35 psi) at 80 °C |
Max. Differential Pressure | Forward 6.9 bar (100 psi) at 25 °C 4.0 bar (58 psi) at 60 °C 2.4 bar (35 psi) at 80 °C Reverse 3.0 bar (44 psi) at 25 °C 1.0 bar (15 psi) at 80 °C |
Effective Filtration Area | 0.58m² / Φ 69-10 inch |
Sterilization
Inline Steam Sterilization | up to 100 forward cycles and 50 reverse cycles ( 135 °C for 30 min < 0.3 bar per cycle ) |
Autoclave | up to 400 cycles (130°C for 30min per cycle) |
Integrity Test Data
Bubble Point | BP: ≥ 0.32 MPa(water), LHPVND(0.22 μm) |
Diffusion Flow | DF: ≤ 20 ml/min/10”@ 0.28 MPa, LHPVND(0.22 μm) |
Flow Rate Characteristics
Extractable(NVR) | <30mg/10" ( Test Procedure:Steaming sterilized for 30min at 121°C, then soaked in the purified water for 24 hours ) |
Oxidability | Meets FDA for Oxide Test ( Test Procdure: Steaming sterilized for 30min at 121°C, then take the sample after purified water washing ) |
Endotoxin | <0.25Eu/ml , according to LAL Test |
Material Safety | Meets USP<88>, for class VI-121°C plastics |
LHPV | 0.1μm | 0.22μm | 0.45μm | |
Diffusion Flow(10″Cartridge @20°C) | ≤30ml/min @3860mbar | ≤20ml/min @2800mbar | / | |
Bubble Point (in water @20°C) | ≥4800mbar | ≥3200mbar | ≥1200mbar | |
DLHPV | 0.1+0.1μm | 0.22+0.1μm | 0.22+0.22μm | 0.45+0.22μm |
Diffusion Flow (10″Cartridge @20°C) | ≤15ml/min @3860mbar | ≤20ml/min @3860mbar | ≤18ml/min @2800mbar | ≤20ml/min @2800mbar |
Bubble Point (in water @20°C) | ≥4800mbar | ≥4800mbar | ≥3200mbar | ≥3200mbar |
The Integrity test is a non-destructive test that can be performed by the user to ensure the filter is installed correctly and ready for operation.
Ordering Infomation
Type | Removal Ratings | End Cap | Nominal Length | Seal Material | Industry |
LHPVND DLHPVNDR | 0010=0.1μm 0022=0.22μm 0045=0.45μm 0065=0.65μm 0100=1.0μm 2222=0.22+0.22μm 2245=0.22+0.45μm 6545=0.64+0.45μm 2210=0.22+0.1μm 4545=0.45+0.45μm 6522=0.65+0.22μm 6510=0.65+0.1μm 4510=0.45+0.1μm | HSF=226 /Fin (PBT Insert) HSC=226 /Flat (PBT Insert) HTF=222 /Fin (PBT Insert) HTC=222 /Flat (PBT Insert) DOE=Double Open End | 05= 5" 10=10" 20=20" 30=30" 40=40" | S=Silicone E=EPDM V=Viton P=PFA/Viton | P=Pharmaceutical |